<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>VRF &#8211; Ess N Ess</title>
	<atom:link href="http://essness.co.in/product-category/airconditioning-solutions/vrf/feed/" rel="self" type="application/rss+xml" />
	<link>http://essness.co.in</link>
	<description></description>
	<lastBuildDate>Tue, 26 May 2020 06:48:32 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.4.5</generator>

<image>
	<url>http://essness.co.in/wp-content/uploads/2019/03/favicon-1.png</url>
	<title>VRF &#8211; Ess N Ess</title>
	<link>http://essness.co.in</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>LG HYDROKIT</title>
		<link>http://essness.co.in/product/lg-hydrokit/</link>
		
		<dc:creator><![CDATA[Saurav]]></dc:creator>
		<pubDate>Wed, 29 Jan 2020 09:54:50 +0000</pubDate>
				<guid isPermaLink="false">http://essness.co.in/?post_type=product&#038;p=10016</guid>

					<description><![CDATA[<h3 class="text-normal">Saving Costs with Highly Energy Efficient Solution</h3>
<section class="module m01 text-dark text-top">
<div class="text-block">

Hydro Kit reduces CO₂ emissions with its highly efficient solution. It is also possible to install equivalent levels of capital costs as a boiler system while minimizing energy bills due to lower operation costs.

</div>
</section><section class="module b05 ">
<div class="container one-column">
<div class="column"></div>
</div>
</section>]]></description>
										<content:encoded><![CDATA[<h3 class="text-normal">Saving Costs with Highly Energy Efficient Solution</h3>
<section class="module m01 text-dark text-top">
<div class="text-block">

Hydro Kit reduces CO₂ emissions with its highly efficient solution. It is also possible to install equivalent levels of capital costs as a boiler system while minimizing energy bills due to lower operation costs.

</div>
</section><section class="module b05 ">
<div class="container one-column">
<div class="column"></div>
</div>
</section>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LG Multi V Water IV Heat Pump</title>
		<link>http://essness.co.in/product/lg-multi-v-water-iv-heat-pump/</link>
		
		<dc:creator><![CDATA[Saurav]]></dc:creator>
		<pubDate>Wed, 29 Jan 2020 09:51:07 +0000</pubDate>
				<guid isPermaLink="false">http://essness.co.in/?post_type=product&#038;p=10012</guid>

					<description><![CDATA[Available in 208-230V with sizes ranging from 6 - 36 tons and in 460V with sizes ranging from 6 - 48 tons

AHRI 1230 certified

Installed indoors which allows a cleaner building exterior

Compact size to fit in small mechanical rooms

Front pipe connections allow easier installation

Stackable units (with field supplied racks)

Stainless steel plate heat exchanger for condenser water, with built in temperature sensor]]></description>
										<content:encoded><![CDATA[Available in 208-230V with sizes ranging from 6 - 36 tons and in 460V with sizes ranging from 6 - 48 tons

AHRI 1230 certified

Installed indoors which allows a cleaner building exterior

Compact size to fit in small mechanical rooms

Front pipe connections allow easier installation

Stackable units (with field supplied racks)

Stainless steel plate heat exchanger for condenser water, with built in temperature sensor]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LG MULTI V S (VRF)</title>
		<link>http://essness.co.in/product/lg-multi-v-s-vrf/</link>
		
		<dc:creator><![CDATA[Saurav]]></dc:creator>
		<pubDate>Wed, 29 Jan 2020 09:45:32 +0000</pubDate>
				<guid isPermaLink="false">http://essness.co.in/?post_type=product&#038;p=10009</guid>

					<description><![CDATA[<h3>Quick Operating Response</h3>
Operation response gets faster and more accurate with pressure sensor. Pressure control gets 14％ faster in cooling mode, improving user comfort.
<h3>Optimal Heat Exchanger Circuit</h3>
<div class="column">

The variable heat exchanger circuit intelligently selects optimal paths for both heating and cooling operation. This increases efficiency up to 5％.

</div>
<div>
<h3>Heat Exchanger with Wide Louver Plus Fin</h3>
<section class="module b05 ">
<div class="container three-column">
<div class="column">

Heat exchanger efficiency is improved up to 7％ with wide louver plus fin by slowing down the frosting and postponing the defrosting operation.
<h3 class="text-normal">6 By-pass Valve</h3>
Compressor reliability is maximized with 6 by-pass valve as it prevents compressor damage caused by excessively compressed refrigerant.
<h3 class="text-normal">High Reliability at All Capacity</h3>
<section class="module m04 text-banner two-column text-light ">For models with capacity below 7HP, rotary compressor is installed while scroll compressor is applied for models with more than 7HP capacity, making it highly reliable and efficient.
<h3>Smart Load Control</h3>
<section class="module b03 related-contents">
<div class="container one-column">
<div class="column">

MULTI V S controls refrigerant temperature according to indoor, outdoor and setting temperatures. This optimizes energy efficiency by saving up to 13％ and maximizes indoor comfort level in cooling/heating modes.

</div>
</div>
</section><section class="module b01 ">
<div class="container one-column">
<div class="column"></div>
</div>
</section></section><section class="module b03 related-contents">
<div class="container one-column">
<div class="column"></div>
</div>
</section>&#160;

</div>
</div>
</section></div>]]></description>
										<content:encoded><![CDATA[<h3>Quick Operating Response</h3>
Operation response gets faster and more accurate with pressure sensor. Pressure control gets 14％ faster in cooling mode, improving user comfort.
<h3>Optimal Heat Exchanger Circuit</h3>
<div class="column">

The variable heat exchanger circuit intelligently selects optimal paths for both heating and cooling operation. This increases efficiency up to 5％.

</div>
<div>
<h3>Heat Exchanger with Wide Louver Plus Fin</h3>
<section class="module b05 ">
<div class="container three-column">
<div class="column">

Heat exchanger efficiency is improved up to 7％ with wide louver plus fin by slowing down the frosting and postponing the defrosting operation.
<h3 class="text-normal">6 By-pass Valve</h3>
Compressor reliability is maximized with 6 by-pass valve as it prevents compressor damage caused by excessively compressed refrigerant.
<h3 class="text-normal">High Reliability at All Capacity</h3>
<section class="module m04 text-banner two-column text-light ">For models with capacity below 7HP, rotary compressor is installed while scroll compressor is applied for models with more than 7HP capacity, making it highly reliable and efficient.
<h3>Smart Load Control</h3>
<section class="module b03 related-contents">
<div class="container one-column">
<div class="column">

MULTI V S controls refrigerant temperature according to indoor, outdoor and setting temperatures. This optimizes energy efficiency by saving up to 13％ and maximizes indoor comfort level in cooling/heating modes.

</div>
</div>
</section><section class="module b01 ">
<div class="container one-column">
<div class="column"></div>
</div>
</section></section><section class="module b03 related-contents">
<div class="container one-column">
<div class="column"></div>
</div>
</section>&#160;

</div>
</div>
</section></div>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LG VRF Multi V IV</title>
		<link>http://essness.co.in/product/lg-vrf-multi-v-iv/</link>
		
		<dc:creator><![CDATA[Saurav]]></dc:creator>
		<pubDate>Wed, 29 Jan 2020 09:26:43 +0000</pubDate>
				<guid isPermaLink="false">http://essness.co.in/?post_type=product&#038;p=10005</guid>

					<description><![CDATA[<h3><strong>LG’s 4th Generation Inverter Compressor</strong></h3>
<h3 class="text-normal">Vapor Injection</h3>
Two-stage compression improves heating efficiency and boosts heating performance even in extremely cold weather (up to -25°C).
<h3><strong>Extended Compressor Speed 15~150Hz</strong></h3>
<ul>
 	<li>Multi V IV compressor elaborately adjusts its speed in respond to required temperature, thus reducing energy loss while providing comfort in a short period of time.</li>
</ul>
<h3><strong>LG’s HIPOR™ (High Pressure Oil Return)</strong></h3>
<ul>
 	<li>LG’s HIPOR™ technology resolves compressor efficiency loss and improves part load efficiency by directly collecting oil to the inside of the compressor.</li>
</ul>
<h3><strong>Smart Oil Return</strong></h3>
<ul>
 	<li>Oil level sensor checks and optimizes compressor oil level in real time, thus enhancing compressor reliability and heating performance.</li>
</ul>
<h3 class="text-normal">Optimal Heat Exchanger Circuit</h3>
<ul>
 	<li>Variable Heat Exchanger Circuit intelligently selects the optimal number of heat exchanging paths to increase efficiency..</li>
</ul>
<h3 class="text-normal">Smart Load Control</h3>
<ul>
 	<li>It adjusts indoor discharge air according to outdoor and indoor temperature. This optimizies energy efficiency and maximizes indoor comfort level in cooling/heating modes.</li>
</ul>
<h3 class="text-normal">Continuous Heating in Defrosting Operation</h3>
<ul>
 	<li class="text-normal">Multi V IV’s advanced defrosting technology provides consistent heating in cold weather.</li>
</ul>
<h3 class="text-normal">Expanded Piping Capabilities</h3>
<ul>
 	<li>Multi V IV boasts long piping capabilities. 1000 meters in total piping length (longest piping length between outdoor &#38; indoor unit is 200 meters).</li>
</ul>
&#160;

&#160;]]></description>
										<content:encoded><![CDATA[<h3><strong>LG’s 4th Generation Inverter Compressor</strong></h3>
<h3 class="text-normal">Vapor Injection</h3>
Two-stage compression improves heating efficiency and boosts heating performance even in extremely cold weather (up to -25°C).
<h3><strong>Extended Compressor Speed 15~150Hz</strong></h3>
<ul>
 	<li>Multi V IV compressor elaborately adjusts its speed in respond to required temperature, thus reducing energy loss while providing comfort in a short period of time.</li>
</ul>
<h3><strong>LG’s HIPOR™ (High Pressure Oil Return)</strong></h3>
<ul>
 	<li>LG’s HIPOR™ technology resolves compressor efficiency loss and improves part load efficiency by directly collecting oil to the inside of the compressor.</li>
</ul>
<h3><strong>Smart Oil Return</strong></h3>
<ul>
 	<li>Oil level sensor checks and optimizes compressor oil level in real time, thus enhancing compressor reliability and heating performance.</li>
</ul>
<h3 class="text-normal">Optimal Heat Exchanger Circuit</h3>
<ul>
 	<li>Variable Heat Exchanger Circuit intelligently selects the optimal number of heat exchanging paths to increase efficiency..</li>
</ul>
<h3 class="text-normal">Smart Load Control</h3>
<ul>
 	<li>It adjusts indoor discharge air according to outdoor and indoor temperature. This optimizies energy efficiency and maximizes indoor comfort level in cooling/heating modes.</li>
</ul>
<h3 class="text-normal">Continuous Heating in Defrosting Operation</h3>
<ul>
 	<li class="text-normal">Multi V IV’s advanced defrosting technology provides consistent heating in cold weather.</li>
</ul>
<h3 class="text-normal">Expanded Piping Capabilities</h3>
<ul>
 	<li>Multi V IV boasts long piping capabilities. 1000 meters in total piping length (longest piping length between outdoor &#38; indoor unit is 200 meters).</li>